UK HQ Your time

Crystallisation-Resistant Design

Temperature Control

Urea solutions crystallise below -11°C (DEF/AdBlue). Our tanks feature integrated heating systems and insulation to maintain optimal storage temperature, preventing costly downtime from crystallised product. Options include electric heat tracing, steam coils, and glycol jacket systems.

Dimensions

  • Diameter Range1000mm - 4000mm
  • Height Range1500mm - 8000mm
  • Capacity Range1,200L - 100,000L
  • Custom SizesAvailable

Temperature Control

  • Heating OptionsElectric/Steam/Glycol
  • Control Range-5°C to +40°C
  • Insulation50-100mm PU foam
  • CrystallisationPrevention system

Materials

  • StandardSS304 / SS316
  • CoatingsEpoxy (optional)
  • InsulationPolyurethane foam
  • CladdingAluminium/SS

Features

  • Level ControlRadar/Ultrasonic
  • DispensingTransfer pump
  • FiltrationIn-line filter
  • QualityISO 22241

Regional Standards & Certifications

Our urea tanks meet DEF/AdBlue standards and are certified for worldwide deployment.

North America

ASME Section VIIIISO 22241API 650

Full DEF compliance for North American markets.

European Union

PED 2014/68/EUCE MarkingAdBlue Certified

Full AdBlue compliance for EU markets.

United Kingdom

UKCA MarkingPressure Equipment Regs

Full UKCA certification for UK market.

Australia & New Zealand

AS 1210WorkSafe NZ

Full compliance with Australian standards.

Rectangular Tank Dimensions & Volumes

Standard rectangular tank configurations with calculated capacities. Custom dimensions available upon request.

Containerised Tanks

  • Length Range1,500mm - 10,000mm
  • Width Range1,200mm - 2,400mm
  • Maximum Height2,300mm
  • Standard Height2,200mm / 2,100mm
  • Volume Range4m³ - 55m³
  • ConfigurationISO Container Compatible

Free-Standing Tanks

  • Length Range1,500mm - 10,000mm
  • Width Range1,200mm - 4,000mm
  • Maximum Height5,000mm
  • Common Heights2,400mm / 3,000mm / 4,000mm
  • Volume Range4m³ - 200m³
  • ConfigurationIndoor/Outdoor Installation
ConfigurationLength (mm)Width (mm)Height (mm)Volume (m³)Volume (Litres)
Containerised TANKS (Max Height: 2,300mm)
Compact C11,5001,2002,2003.963,960
Compact C22,0001,2002,2005.285,280
Standard C32,5001,5002,2008.258,250
Standard C43,0001,5002,2009.909,900
Medium C54,0001,8002,20015.8415,840
Medium C65,0002,0002,20022.0022,000
Large C76,0002,2002,20029.0429,040
Large C87,0002,3002,20035.4235,420
XLarge C98,0002,3002,20040.4840,480
Max C1010,0002,4002,30055.2055,200
FREE-STANDING TANKS - Low Profile (Height: 2,400mm)
Low L12,0001,5002,4007.207,200
Low L23,0002,0002,40014.4014,400
Low L34,0002,5002,40024.0024,000
Low L45,0002,5002,40030.0030,000
Low L56,0003,0002,40043.2043,200
Low L68,0003,0002,40057.6057,600
Low L710,0003,5002,40084.0084,000
FREE-STANDING TANKS - Medium Height (Height: 3,000mm)
Medium M12,0001,5003,0009.009,000
Medium M23,0002,0003,00018.0018,000
Medium M34,0002,5003,00030.0030,000
Medium M45,0002,5003,00037.5037,500
Medium M56,0003,0003,00054.0054,000
Medium M68,0003,0003,00072.0072,000
Medium M710,0003,5003,000105.00105,000
FREE-STANDING TANKS - High Profile (Height: 4,000mm - 5,000mm)
High H12,5002,0004,00020.0020,000
High H23,0002,5004,00030.0030,000
High H34,0003,0004,00048.0048,000
High H45,0003,0004,00060.0060,000
High H56,0003,5004,00084.0084,000
High H68,0003,5004,000112.00112,000
Max H78,0004,0005,000160.00160,000
Max H810,0004,0005,000200.00200,000

Important Notes:

  • All dimensions are internal (usable) dimensions
  • Volumes calculated using rectangular prism formula: L × W × H
  • Actual working capacity typically 90-95% of total volume
  • Containerised tanks engineered for ISO container compatibility (width ≤ 2,400mm)
  • Free-standing tanks can be customised beyond standard dimensions
  • Wall thickness varies based on material, pressure, and chemical compatibility

SCADA & Control Systems

Optional integrated automation for remote monitoring and control of your urea storage operations.

SCADA Ready

Our urea tanks can be equipped with comprehensive SCADA integration for real-time monitoring of level, temperature, and crystallisation prevention systems. Remote access enables 24/7 oversight of your DEF/AdBlue storage operations with automated alerts for low levels or temperature excursions.

Level MonitoringTemperature ControlCrystallisation AlertsRemote AlarmsUsage Reporting
Learn About SCADA Integration

Complete Your Urea Storage System

Need a urea storage solution?

Contact our engineering team to discuss your DEF/AdBlue or industrial urea storage requirements.

Industries We Serve

Our expertise spans multiple industries with sector-specific water treatment solutions.