UK HQ Your time

Ebara 3L 80-250

End Suction Long-Coupled

Identification
ManufacturerEbara
Series3 Series
Model / size3L 80-250
Pump typeEnd Suction Long-Coupled
Spec codePS-ES-034
Duty & power
Min flow50 m³/hr
Max flow200 m³/hr
Min head15 m
Max head70 m
Max power45 kW
NPSHr5.7 m
Efficiency at BEP72 %
Drive & electrical
Starting methodSoft Starter or VFD (mandatory for >15kW to limit starting current)
VFD compatibleYes (10-60 Hz)
Motor IE classIE3 (mandatory EU/MEPS) / IE4 optional
Insulation classClass F (155°C)
IP ratingIP55
Materials & sealing
CasingCast Iron
ImpellerBronze
ShaftSS 416
Seal typeMechanical Seal
API seal planPlan 11 (internal recirculation) — standard single seal
Application
ServicePotable Water, Raw Water
Key featuresLarge end suction, robust

← Back to the Pump Selector

Pump specification, curve, seal plan, maintenance & troubleshooting

A complete, shareable page for a single pump. It plots the performance curve (head, efficiency and NPSHr against flow, with the best-efficiency point marked, or dosing flow against stroke), decodes the API 682 / ISO 21049 mechanical seal plan, and lists the full specification — duty and operating range, drive and motor, materials of construction, build and reliability, connections, weight and certifications. Pop-up panels give the type-specific preventive-maintenance schedule (daily to annual tasks with procedures) and a troubleshooting guide (symptoms, probable causes and recommended solutions).

Run a centrifugal pump near its BEP and keep dosing pumps in their recommended stroke band. Data is from the engineering reference database — confirm against the manufacturer's certified curve before procurement.

Industries We Serve

Our expertise spans multiple industries with sector-specific water treatment solutions.

Related Pages