Submersible Seawater
| Identification | |
| Manufacturer | Flygt |
| Series | N-Technology |
| Model / size | N 3153 SH |
| Pump type | Submersible Seawater |
| Spec code | PS-SM-038 |
| Duty & power | |
| Min flow | 50 m³/hr |
| Max flow | 200 m³/hr |
| Min head | 10 m |
| Max head | 60 m |
| Max power | 37 kW |
| NPSHr | 1.5 m |
| Efficiency at BEP | 72 % |
| Drive & electrical | |
| Starting method | Soft Starter or VFD (mandatory for >15kW to limit starting current) |
| VFD compatible | Yes (10-60 Hz, soft start recommended) |
| Motor IE class | IE3 (mandatory EU/MEPS) / IE4 optional |
| Insulation class | Class F (155°C) standard |
| IP rating | IP68 |
| Materials & sealing | |
| Casing | Super Duplex 2507 |
| Impeller | Super Duplex 2507 |
| Shaft | Super Duplex 2507 |
| Seal type | Mechanical Seal |
| API seal plan | Plan 11 / Plan 13 (vent) — canned motor, no external seal |
| Application | |
| Service | Seawater, Large Volume |
| Key features | Flygt N-technology, super duplex |
A complete, shareable page for a single pump. It plots the performance curve (head, efficiency and NPSHr against flow, with the best-efficiency point marked, or dosing flow against stroke), decodes the API 682 / ISO 21049 mechanical seal plan, and lists the full specification — duty and operating range, drive and motor, materials of construction, build and reliability, connections, weight and certifications. Pop-up panels give the type-specific preventive-maintenance schedule (daily to annual tasks with procedures) and a troubleshooting guide (symptoms, probable causes and recommended solutions).
Run a centrifugal pump near its BEP and keep dosing pumps in their recommended stroke band. Data is from the engineering reference database — confirm against the manufacturer's certified curve before procurement.
Our expertise spans multiple industries with sector-specific water treatment solutions.
Explore closely-related tools, references and guides
Send your influent analysis and our engineers assess your process and recommend a tailored treatment solution — free, confidential and no obligation.
Select the regulatory standard for your country — it sets which parameters we need for a compliance-aware process assessment.
Required parameters for the chosen standard are flagged on the sample form. You can still submit a partial set and we will advise what else to test.
Your sample is stored against your company so we can track the project. Provide a company name or email as a minimum.