Solenoid Diaphragm
| Identification | |
| Manufacturer | IWAKI |
| Series | EHN Series |
| Model / size | EHN-B21 |
| Dosing type | Solenoid Diaphragm |
| Pump class | Category A — Solenoid diaphragm, low-flow precision dosing. Stroke frequency 180 SPM. Accuracy ±2.0%. Best for: intermittent duty, water treatment, swimming pools. Limit: 3.5 L/h, 10.0 bar. |
| Spec code | DSG-038 |
| Dosing duty | |
| Min flow | 0.5 L/h |
| Max flow | 3.5 L/h |
| Max pressure | 10 bar |
| Dosing accuracy | 2 % |
| Stroke frequency | 180 spm |
| Suction lift | 1.5 m |
| Max viscosity | 300 cP |
| Control & drive | |
| Control type | Manual + Pulse + Analog |
| Stroke adjustment | Manual 0-100% |
| Power | 27 W |
| Supply voltage | 100-230 VAC V |
| IP rating | IP55 |
| Materials & chemical | |
| Liquid end | PP |
| Diaphragm | PTFE/EPDM |
| Valve / ball | Ceramic |
| pH range | 0-14 (full range — HF, concentrated acids, caustic) |
| Chemical compatibility | Chlorine, pH adjustment, coagulants |
| Application | |
| Service | Water Treatment, Industrial Dosing |
| Key features | IWAKI EHN-B21, 3.5 L/h at 10 bar, PP liquid end, pulse and analog input, 180 SPM |
A complete, shareable page for a single pump. It plots the performance curve (head, efficiency and NPSHr against flow, with the best-efficiency point marked, or dosing flow against stroke), decodes the API 682 / ISO 21049 mechanical seal plan, and lists the full specification — duty and operating range, drive and motor, materials of construction, build and reliability, connections, weight and certifications. Pop-up panels give the type-specific preventive-maintenance schedule (daily to annual tasks with procedures) and a troubleshooting guide (symptoms, probable causes and recommended solutions).
Run a centrifugal pump near its BEP and keep dosing pumps in their recommended stroke band. Data is from the engineering reference database — confirm against the manufacturer's certified curve before procurement.
Our expertise spans multiple industries with sector-specific water treatment solutions.
Explore closely-related tools, references and guides
Send your influent analysis and our engineers assess your process and recommend a tailored treatment solution — free, confidential and no obligation.
Select the regulatory standard for your country — it sets which parameters we need for a compliance-aware process assessment.
Required parameters for the chosen standard are flagged on the sample form. You can still submit a partial set and we will advise what else to test.
Your sample is stored against your company so we can track the project. Provide a company name or email as a minimum.