UK HQ Your time

Layne Bowler VT 12 inch

Vertical Turbine

Identification
ManufacturerLayne Bowler
SeriesVT
Model / sizeVT 12 inch
Pump typeVertical Turbine
Spec codePS-VT-024
Duty & power
Min flow200 m³/hr
Max flow1200 m³/hr
Min head15 m
Max head300 m
Max power400 kW
NPSHr4 m
Efficiency at BEP78 %
Drive & electrical
Starting methodVFD mandatory (liquid coupling or variable speed for large motors)
VFD compatibleYes (consult factory)
Motor IE classIE3 (mandatory EU/MEPS) / IE4 optional
Insulation classClass F (155°C)
IP ratingIP55
Materials & sealing
CasingCast Iron / Bronze
ImpellerBronze
ShaftSS 416
Seal typeMechanical Seal / Packing
API seal planPlan 11 (standard) + Plan 62 (quench steam) optional
Application
ServicePotable Water, River Intake
Key features12 inch, large capacity

← Back to the Pump Selector

Pump specification, curve, seal plan, maintenance & troubleshooting

A complete, shareable page for a single pump. It plots the performance curve (head, efficiency and NPSHr against flow, with the best-efficiency point marked, or dosing flow against stroke), decodes the API 682 / ISO 21049 mechanical seal plan, and lists the full specification — duty and operating range, drive and motor, materials of construction, build and reliability, connections, weight and certifications. Pop-up panels give the type-specific preventive-maintenance schedule (daily to annual tasks with procedures) and a troubleshooting guide (symptoms, probable causes and recommended solutions).

Run a centrifugal pump near its BEP and keep dosing pumps in their recommended stroke band. Data is from the engineering reference database — confirm against the manufacturer's certified curve before procurement.

Industries We Serve

Our expertise spans multiple industries with sector-specific water treatment solutions.

Related Pages

Explore closely-related tools, references and guides