UK HQ Your time

Engineered for Oil & Gas Applications

Production-Proven Design

Our formation water tanks are specifically engineered for upstream oil and gas operations, featuring specialised coatings that resist hydrogen sulphide (H2S), carbon dioxide (CO2), and chloride attack common in produced water.

Dimensions

  • Diameter Range1000mm - 4000mm
  • Height Range1500mm - 8000mm
  • Capacity Range1,200L - 100,000L
  • Custom SizesAvailable

Design Parameters

  • Design PressureAtmospheric - 10 bar
  • Design Temperature-20°C to +150°C
  • Corrosion Allowance1mm - 3mm
  • Seismic DesignZone 4 available

Materials & Coatings

  • Shell MaterialCarbon Steel / SS316
  • Internal CoatingEpoxy / Glassflake
  • External FinishPaint / Hot-dip Galv
  • Coating Thickness500-1500 microns

Fittings & Accessories

  • Manway500mm - 600mm
  • Inlet/OutletANSI/DIN flanges
  • VentPressure/vacuum
  • Level ControlRadar/Ultrasonic

Regional Standards & Certifications

Our formation water tanks are certified for worldwide deployment with full documentation packages.

North America

ASME Section VIIIASME U StampAPI 620/650NACE MR0175

Full compliance with ASME Boiler and Pressure Vessel Code for North American oilfield operations.

European Union

PED 2014/68/EUCE MarkingEN 13445ATEX (optional)

PED compliant with CE marking for European oil and gas facilities.

Middle East

SASOADNOCKNPCQP Standards

Approved for major Middle East oil and gas operators with local certification.

Asia Pacific

AS 1210GB 150JIS B 8265DOSH

Compliant with Asia Pacific pressure vessel standards and local regulations.

Rectangular Tank Dimensions & Volumes

Standard rectangular tank configurations with calculated capacities. Custom dimensions available upon request.

Containerised Tanks

  • Length Range1,500mm - 10,000mm
  • Width Range1,200mm - 2,400mm
  • Maximum Height2,300mm
  • Standard Height2,200mm / 2,100mm
  • Volume Range4m³ - 55m³
  • ConfigurationISO Container Compatible

Free-Standing Tanks

  • Length Range1,500mm - 10,000mm
  • Width Range1,200mm - 4,000mm
  • Maximum Height5,000mm
  • Common Heights2,400mm / 3,000mm / 4,000mm
  • Volume Range4m³ - 200m³
  • ConfigurationIndoor/Outdoor Installation
ConfigurationLength (mm)Width (mm)Height (mm)Volume (m³)Volume (Litres)
Containerised TANKS (Max Height: 2,300mm)
Compact C11,5001,2002,2003.963,960
Compact C22,0001,2002,2005.285,280
Standard C32,5001,5002,2008.258,250
Standard C43,0001,5002,2009.909,900
Medium C54,0001,8002,20015.8415,840
Medium C65,0002,0002,20022.0022,000
Large C76,0002,2002,20029.0429,040
Large C87,0002,3002,20035.4235,420
XLarge C98,0002,3002,20040.4840,480
Max C1010,0002,4002,30055.2055,200
FREE-STANDING TANKS - Low Profile (Height: 2,400mm)
Low L12,0001,5002,4007.207,200
Low L23,0002,0002,40014.4014,400
Low L34,0002,5002,40024.0024,000
Low L45,0002,5002,40030.0030,000
Low L56,0003,0002,40043.2043,200
Low L68,0003,0002,40057.6057,600
Low L710,0003,5002,40084.0084,000
FREE-STANDING TANKS - Medium Height (Height: 3,000mm)
Medium M12,0001,5003,0009.009,000
Medium M23,0002,0003,00018.0018,000
Medium M34,0002,5003,00030.0030,000
Medium M45,0002,5003,00037.5037,500
Medium M56,0003,0003,00054.0054,000
Medium M68,0003,0003,00072.0072,000
Medium M710,0003,5003,000105.00105,000
FREE-STANDING TANKS - High Profile (Height: 4,000mm - 5,000mm)
High H12,5002,0004,00020.0020,000
High H23,0002,5004,00030.0030,000
High H34,0003,0004,00048.0048,000
High H45,0003,0004,00060.0060,000
High H56,0003,5004,00084.0084,000
High H68,0003,5004,000112.00112,000
Max H78,0004,0005,000160.00160,000
Max H810,0004,0005,000200.00200,000

Important Notes:

  • All dimensions are internal (usable) dimensions
  • Volumes calculated using rectangular prism formula: L × W × H
  • Actual working capacity typically 90-95% of total volume
  • Containerised tanks engineered for ISO container compatibility (width ≤ 2,400mm)
  • Free-standing tanks can be customised beyond standard dimensions
  • Wall thickness varies based on material, pressure, and chemical compatibility

Oil & Gas Industry Applications

Produced Water Storage

Storage of formation water from oil and gas production wells before treatment or disposal.

Well Test Storage

Temporary storage during well testing and flowback operations.

Water Treatment Buffer

Buffer storage upstream of water treatment systems for oil removal.

Water Injection

Storage of filtered formation water prior to reinjection for reservoir pressure maintenance.

Complete Your Storage System

SCADA & Control Systems

Integrated monitoring and control for remote oilfield operations and unmanned facilities.

SCADA Ready

Our formation water tanks are engineered for integration with oilfield SCADA systems, enabling remote monitoring of level, pressure, and H2S levels from central control rooms. Essential for unmanned platforms and remote wellpad operations with satellite or cellular connectivity.

Level MonitoringPressure MonitoringH2S DetectionRemote AlarmsSatellite Connectivity
Learn About SCADA Integration

Need formation water storage?

Contact our oil and gas team for project-specific solutions.

Industries We Serve

Our expertise spans multiple industries with sector-specific water treatment solutions.